Facebook
TwitterAttribution 4.0 (CC BY 4.0)https://creativecommons.org/licenses/by/4.0/
License information was derived automatically
# General Metadata for Hull Springs Restored Wetland Sampling Station ## Files Specific metadata for each deployment and sensor can be found as text files with the file format of: HS_wetland_DO_YYYY-MM-DD_metadata.txt HS_wetland_pressure_trans_YYYY-MM-DD_metadata.txt HS_wetland_CT_YYYY-MM-DD_metadata.txt Where YYYY-MM-DD is the date that the sampling period ended. NOTE: The metadata in the above file is collected from the data logger and does not have all of fields present in the final data set, because some were created during data cleaning. Details on how the data were cleaned and variables created can be found at in the cleaning scripts on Gitlab [https://gitlab.com/leo147/leo/-/tree/master/lab_notebook/data_processing/cleaning_scripts](https://gitlab.com/leo147/leo/-/tree/master/lab_notebook/data_processing/cleaning_scripts). ## File Created * 2021-06-16 by KF ## File Modified * 2021-07-22 by KF - added general metadata for the pressure transducer and the CT sensor. ## Description These data are from the sampling station in the restored wetland at Hull Springs. The sensors are in the NE corner of the shallow pond portion of the restored wetland (38.119289, -76.667252). All data are CC-BY and should be cited using the DOI available at https://zenodo.org/communities/leo/ ## Station Specifics The specific at each site are: * Temperature (dC) and Dissolved Oxygen (mg/l) are collected with a Onset HOBO U26-001 Dissolved Oxygen Logger * Temperature (dC) and Pressure (mmHg) are collected with an Onset HOBO U20-001-01 Water Level Logger * Temperature (dC) and Conductivity are collected with an Onset HOBO U24-001 Conductivity Logger The sensors are sampled every 15 minutes ## Measurement Parameters, units, and Variable Names * date.time - the date and time that the record was collected, reported in POSIX standard time (YYYY-MM-DD HH:MM:SS) * date.time.adj - the date and time of the pressure measurement that was adjusted to match the barometric pressure measurement from the weather station. * observation - the incremental number of each observation * timestamp - the data and time that the record was collected, as reported by the data logger (MM/DD/YY HH:MM:SS A/PM) * DO - the concentration of dissolved oxygen in the water (mg/L) * Temp - the temperature of the water (dC) * Pressure - the pressure recorded by the underwater pressure transducer (mmHg) * Low_Range_CT - the conductivity read from 0 - 2500 uS/cm (uS/cm) * Full_Range_CT - the conductivity read from 0 - 15000 uS/cm (mmHg)
Facebook
TwitterMultibeam swath bathymetry data at the Porcupine Abyssal Plain Sustained Observatory (PAP-SO) were collected with a hull-mounted Kongsberg EM122 echosounder (12 kHz) during RRS Discovery cruise DY130 (Chief Scientist Susan Hartman) between March-April 2021. The cruise was conducted to map Whittard Canyon, a deep ocean canyon in the Bay of Biscay, and the Porcupine Abyssal Plain Sustained Observatory (PAP-SO), a fixed-point, open-ocean, scientific observatory. The data were edited using Caris HIPS software by Catherine Wardell and gridded at 50 m spacing in a WGS84 UTM Zone 28N. The vertical datum of the data is matched to mean sea level (MSL). They were exported as longitude-latitude-depth triples. Funding was provided to CLASS (Climate Linked Atlantic Sector Science), the National Capability Single Sector Marine Research Programme by NERC.
Facebook
TwitterAttribution 4.0 (CC BY 4.0)https://creativecommons.org/licenses/by/4.0/
License information was derived automatically
General Metadata for Hull Springs Dock-YSI Sampling Station
Files
Specific metadata for each deployment can be found as text files with the file format of:
HS_YSI_YYYY-MM-DD_metadata.txt
HS_dock_pressure_trans_YYYY-MM-DD_metadata.txt
Where YYYY-MM-DD is the date that the sampling period ended.
NOTE: The metadata in the above file is collected from the data logger and does not have all of fields present in the final data set, because some were created during data cleaning.
File Created
File Modified
Description
These data are from the sampling station in Aimes Creek on the Camp House dock (38.125367, -76.659537).
* Physical and chemical water data are collected with a YSI EXO2 sonde.
* Temperature (dC) and Pressure (KPa) are collected with an Onset HOBO U20-001-01-Ti Water Level Logger
All data are CC-BY and should be cited using the DOI available at https://zenodo.org/communities/leo/
Station Specifics
The sensors are sampled every 15 minutes
Measurements Parameters, units, and Variable Names
Facebook
TwitterAttribution 4.0 (CC BY 4.0)https://creativecommons.org/licenses/by/4.0/
License information was derived automatically
# General Metadata for Hull Springs Farm Atmospheric Sampling Station ## Files Specific metadata for each deployment can be found as text files with the file format of: HSF_weather_YYYY-MM-DD_metadata.txt Where YYYY-MM-DD is the date that the sampling period ended. ## File Created * 2019-10-27 by KF ## File Modified ## Description These data are from a weather station installed at Hull Springs Farm near the "Yellow House" (38.121683, -76.666781) as part of the Longwood Environmental Observatory. All data are CC-BY and should be cited using the DOI available at https://zenodo.org/communities/leo/ ## Station Specifics The specific at each site are: * Barometric Pressure (mmHg) - Campbell Scientific CS100 Barometric Pressure Sensor * Light Flux Density (kW/m^2) - Campbell Scientific Pyranometer CS300 * Light Total Flux (kJ/m^2) - Campbell Scientific Pyranometer CS300 * Rainfall (mm) - Texas Electronics TE525 Tipping Bucket * Temperature (dC) - Campbell Scientific CS215 Temperature and Relative Humidity Sensor * Relative Humidity (%) - Campbell Scientific CS215 Temperature and Relative Humidity Sensor * Wind Speed (m/s) - RM Young 05103 Wind Speed and Direction Sensor * Wind Direction (degrees from true N) - RM Young 05103 Wind Speed and Direction Sensor * Data Collection - Campbell Scientific CR200 Data Logger * The sensors are sampled every 15 minutes ## Measurement Parameters, units, and Variable Names * DATE - the date that the record was collected (YYYY-MM-DD) * TIMESTAMP - the date and time that the record was collected (YYYY-MM-DD HH:MM:SS) * RECORD.x - a unique identifying number provided from the data logger for table 1 from the original downloaded data. * BattV_Avg - The average battery voltage (Volts) * BattV - The battery voltage at the time of the sampling (Volts) * BP_mmHg_Avg - The average barometric pressure over the sampling interval (mmHg) * BP_mmHg_Std - The standard deviation of the average barometric pressure (mmHg) * BP_mmHg - The barometric pressure at the time of the sampling (mmHg) * Rain_mm_Tot - The total rainfall during the sampling interval (mm) * AirTC_Avg - The average air temperature during the sampling interval (dC) * AirTC_Std - The standard deviation of the average air temperature (dC) * AirTC - the air temperature at the time of the sampling (dC) * RH - the relative humidity at the time of the sampling (%) * RH_Min - the minimum relative humidity recorded (%) * RH_TMn - the time that the minimum relative humidity measurement occurred (YYYY-MM-DD HH:MM:SS) * RH_Max - the maximum relative humidity recorded (%) * RH_TMx - the time that the maximum relative humidity measurement occurred (YYYY-MM-DD HH:MM:SS) * RECORD.y - a unique identifying number provided from the data logger for table 1 from the original downloaded data. * BattV_Min - the minimum battery voltage (Volts) * SlrkW_Avg - the average light flux density during the sampling interval (kW/m^2) * SlrkW_Std - the standard deviation of the average light flux density (kW/m^2) * SlrkW - the light flux density at the time of the sampling (kW/m^2) * SlrMJ_Tot - the total light flux (MJ/m^2) * WS_ms_Avg - the average wind speed during the sampling interval (m/s) * WS_ms_Std - the standard deviation of the average wind speed (m/s) * WS_ms - the wind speed at the time of the sampling event (m/s) * WindDir - the wind direction at the time of the sampling event (degrees from true N) * WS_ms_S_WVT - the average wind speed over the previous 15 minutes (m/s) * WindDir_D1_WVT - the average wind direction over the previous 15 minutes (degrees from true N) * WindDir_SD1_WVT - the standard deviation of the average wind direction over the previous 15 minutes (degrees from true N)
Not seeing a result you expected?
Learn how you can add new datasets to our index.
Facebook
TwitterAttribution 4.0 (CC BY 4.0)https://creativecommons.org/licenses/by/4.0/
License information was derived automatically
# General Metadata for Hull Springs Restored Wetland Sampling Station ## Files Specific metadata for each deployment and sensor can be found as text files with the file format of: HS_wetland_DO_YYYY-MM-DD_metadata.txt HS_wetland_pressure_trans_YYYY-MM-DD_metadata.txt HS_wetland_CT_YYYY-MM-DD_metadata.txt Where YYYY-MM-DD is the date that the sampling period ended. NOTE: The metadata in the above file is collected from the data logger and does not have all of fields present in the final data set, because some were created during data cleaning. Details on how the data were cleaned and variables created can be found at in the cleaning scripts on Gitlab [https://gitlab.com/leo147/leo/-/tree/master/lab_notebook/data_processing/cleaning_scripts](https://gitlab.com/leo147/leo/-/tree/master/lab_notebook/data_processing/cleaning_scripts). ## File Created * 2021-06-16 by KF ## File Modified * 2021-07-22 by KF - added general metadata for the pressure transducer and the CT sensor. ## Description These data are from the sampling station in the restored wetland at Hull Springs. The sensors are in the NE corner of the shallow pond portion of the restored wetland (38.119289, -76.667252). All data are CC-BY and should be cited using the DOI available at https://zenodo.org/communities/leo/ ## Station Specifics The specific at each site are: * Temperature (dC) and Dissolved Oxygen (mg/l) are collected with a Onset HOBO U26-001 Dissolved Oxygen Logger * Temperature (dC) and Pressure (mmHg) are collected with an Onset HOBO U20-001-01 Water Level Logger * Temperature (dC) and Conductivity are collected with an Onset HOBO U24-001 Conductivity Logger The sensors are sampled every 15 minutes ## Measurement Parameters, units, and Variable Names * date.time - the date and time that the record was collected, reported in POSIX standard time (YYYY-MM-DD HH:MM:SS) * date.time.adj - the date and time of the pressure measurement that was adjusted to match the barometric pressure measurement from the weather station. * observation - the incremental number of each observation * timestamp - the data and time that the record was collected, as reported by the data logger (MM/DD/YY HH:MM:SS A/PM) * DO - the concentration of dissolved oxygen in the water (mg/L) * Temp - the temperature of the water (dC) * Pressure - the pressure recorded by the underwater pressure transducer (mmHg) * Low_Range_CT - the conductivity read from 0 - 2500 uS/cm (uS/cm) * Full_Range_CT - the conductivity read from 0 - 15000 uS/cm (mmHg)