1 dataset found
  1. f

    Participant demographic data.

    • plos.figshare.com
    xls
    Updated Jun 14, 2023
    Share
    FacebookFacebook
    TwitterTwitter
    Email
    Click to copy link
    Link copied
    Close
    Cite
    Jessica M. Yiannos; Christofer W. Bester; Christopher Zhao; Barbara Gell; Dona M. P. Jayakody (2023). Participant demographic data. [Dataset]. http://doi.org/10.1371/journal.pone.0286986.t001
    Explore at:
    xlsAvailable download formats
    Dataset updated
    Jun 14, 2023
    Dataset provided by
    PLOS ONE
    Authors
    Jessica M. Yiannos; Christofer W. Bester; Christopher Zhao; Barbara Gell; Dona M. P. Jayakody
    License

    Attribution 4.0 (CC BY 4.0)https://creativecommons.org/licenses/by/4.0/
    License information was derived automatically

    Description

    ObjectiveCochlear Implant (CI) programming based on subjective psychophysical fine-tuning of loudness scaling involves active participation and cognitive skills and thus may not be appropriate for difficult-to-condition populations. The electrically evoked stapedial reflex threshold (eSRT) is an objective measure that is suggested to provide clinical benefit to CI programming. This study aimed to compare speech reception outcomes between subjective and eSRT objectively determined CI maps for adult MED-EL recipients. The effect of cognitive skills on these skills was further assessed.MethodsTwenty-seven post lingually hearing-impaired MED-EL CI recipients were recruited, 6 with mild cognitive impairment (MCI– 4 male, 79 years ± 5), 21 with normal cognitive function (5 male, 63 years ± 12). Two MAPs were generated: a subjective MAP and an objective MAP in which eSRTs determined maximum comfortable levels (M-Levels). Participants were randomly divided into two groups. Group A trialled the objective MAP for two weeks before returning for outcome assessment. During the following two weeks, Group A trialled the subjective MAP before returning for outcome assessment. Group B trialled MAPs in reverse. Outcome measures included the Hearing Implant Sound Quality Index (HISQUI), Consonant-Nucleus-Consonant (CNC) word test, and Bamford-Kowal-Bench Speech-in-Noise (BKB-SIN) test.ResultseSRT based MAPS were obtained in 23 of the participants. A strong relationship was demonstrated between global charge between eSRT-based and psychophysical-based M-Levels (r = 0.89, p < .001). The Montreal Cognitive Assessment for the Hearing Impaired (MoCA-HI) testing identified 6 CI recipients with MCI (MoCA-HI total score ≤23). The MCI group was older (63, 79 years), but were not otherwise different in sex, duration of hearing loss or duration of CI use. For all patients, no significant differences were found for sound quality or speech in quiet scores between eSRT-based and psychophysical-based MAPs. However, psychophysically determined MAPs showed significantly better speech-in-noise reception (6.74 vs 8.20-dB SNR, p = .34). MoCA-HI scores showed a significant, moderate negative correlation with BKB SIN for both MAP approaches (Kendall’s Tau B, p = .015 and p = .008), with no effect on the difference between MAP approaches.ConclusionResults indicate eSRT-based methods provide poorer outcomes than psychophysical-based method. While speech-in-noise reception is correlated with MoCA-HI score, this affected both behaviourally and objectively determined MAPs. The results suggest fair confidence in the eSRT-based method as a guide for setting M-Level for difficult-to-condition CI populations in simple listening conditions.

  2. Not seeing a result you expected?
    Learn how you can add new datasets to our index.

Share
FacebookFacebook
TwitterTwitter
Email
Click to copy link
Link copied
Close
Cite
Jessica M. Yiannos; Christofer W. Bester; Christopher Zhao; Barbara Gell; Dona M. P. Jayakody (2023). Participant demographic data. [Dataset]. http://doi.org/10.1371/journal.pone.0286986.t001

Participant demographic data.

Related Article
Explore at:
xlsAvailable download formats
Dataset updated
Jun 14, 2023
Dataset provided by
PLOS ONE
Authors
Jessica M. Yiannos; Christofer W. Bester; Christopher Zhao; Barbara Gell; Dona M. P. Jayakody
License

Attribution 4.0 (CC BY 4.0)https://creativecommons.org/licenses/by/4.0/
License information was derived automatically

Description

ObjectiveCochlear Implant (CI) programming based on subjective psychophysical fine-tuning of loudness scaling involves active participation and cognitive skills and thus may not be appropriate for difficult-to-condition populations. The electrically evoked stapedial reflex threshold (eSRT) is an objective measure that is suggested to provide clinical benefit to CI programming. This study aimed to compare speech reception outcomes between subjective and eSRT objectively determined CI maps for adult MED-EL recipients. The effect of cognitive skills on these skills was further assessed.MethodsTwenty-seven post lingually hearing-impaired MED-EL CI recipients were recruited, 6 with mild cognitive impairment (MCI– 4 male, 79 years ± 5), 21 with normal cognitive function (5 male, 63 years ± 12). Two MAPs were generated: a subjective MAP and an objective MAP in which eSRTs determined maximum comfortable levels (M-Levels). Participants were randomly divided into two groups. Group A trialled the objective MAP for two weeks before returning for outcome assessment. During the following two weeks, Group A trialled the subjective MAP before returning for outcome assessment. Group B trialled MAPs in reverse. Outcome measures included the Hearing Implant Sound Quality Index (HISQUI), Consonant-Nucleus-Consonant (CNC) word test, and Bamford-Kowal-Bench Speech-in-Noise (BKB-SIN) test.ResultseSRT based MAPS were obtained in 23 of the participants. A strong relationship was demonstrated between global charge between eSRT-based and psychophysical-based M-Levels (r = 0.89, p < .001). The Montreal Cognitive Assessment for the Hearing Impaired (MoCA-HI) testing identified 6 CI recipients with MCI (MoCA-HI total score ≤23). The MCI group was older (63, 79 years), but were not otherwise different in sex, duration of hearing loss or duration of CI use. For all patients, no significant differences were found for sound quality or speech in quiet scores between eSRT-based and psychophysical-based MAPs. However, psychophysically determined MAPs showed significantly better speech-in-noise reception (6.74 vs 8.20-dB SNR, p = .34). MoCA-HI scores showed a significant, moderate negative correlation with BKB SIN for both MAP approaches (Kendall’s Tau B, p = .015 and p = .008), with no effect on the difference between MAP approaches.ConclusionResults indicate eSRT-based methods provide poorer outcomes than psychophysical-based method. While speech-in-noise reception is correlated with MoCA-HI score, this affected both behaviourally and objectively determined MAPs. The results suggest fair confidence in the eSRT-based method as a guide for setting M-Level for difficult-to-condition CI populations in simple listening conditions.

Search
Clear search
Close search
Google apps
Main menu