  1. Inflation test on eye globe for: Experimental evaluation of stiffening...

    • zenodo.org
    • data.niaid.nih.gov
    • +2more
    bin
    Updated Jun 3, 2022
    Share
    FacebookFacebook
    TwitterTwitter
    Email
    Click to copy link
    Link copied
    Close
    Cite
    Shao-Hsuan Chang; Shao-Hsuan Chang; Yi-Chen Li; Dong Zhou; Ashkan Eliasy; Yi-Chen Li; Ahmed Elsheikh; Yi-Chen Li; Dong Zhou; Ashkan Eliasy; Yi-Chen Li; Ahmed Elsheikh (2022). Inflation test on eye globe for: Experimental evaluation of stiffening effect induced by UVA/riboflavin corneal cross-linking using intact porcine eye globes [Dataset]. http://doi.org/10.5061/dryad.z8w9ghx9f
    Explore at:
    binAvailable download formats
    Dataset updated
    Jun 3, 2022
    Dataset provided by
    Zenodohttp://zenodo.org/
    Authors
    Shao-Hsuan Chang; Shao-Hsuan Chang; Yi-Chen Li; Dong Zhou; Ashkan Eliasy; Yi-Chen Li; Ahmed Elsheikh; Yi-Chen Li; Dong Zhou; Ashkan Eliasy; Yi-Chen Li; Ahmed Elsheikh
    License

    CC0 1.0 Universal Public Domain Dedicationhttps://creativecommons.org/publicdomain/zero/1.0/
    License information was derived automatically

    Description

    UVA/riboflavin corneal cross-linking (CXL) is a common used approach to treat progressive keratoconus. This study aims to investigate the alteration of corneal stiffness following CXL by mimicking the inflation of the eye under the in vivo loading conditions. Seven paired porcine eye globes were involved in the inflation test to examine the corneal behaviour. Cornea-only model was constructed using the finite element method, without considering the deformation contribution from sclera and limbus. Inverse analysis was conducted to calibrate the non-linear material behaviours in order to reproduce the inflation test. The corneal stress and strain values were then extracted from the finite element models and tangent modulus was calculated under stress level at 0.03 MPa. UVA/riboflavin cross-linked corneas displayed a significant increase in the material stiffness. At the IOP of 27.25 mmHg, the average displacements of corneal apex were 307 ± 65 μm and 437 ± 63 μm (p = 0.02) in CXL and PBS corneas, respectively. Comparisons performed on tangent modulus ratios at a stress of 0.03 MPa, the tangent modulus measured in the corneas treated with the CXL was 2.48 ± 0.69, with a 43±24% increase comparing to its PBS control. The data supported that corneal material properties can be well-described using this inflation methods following CXL. The inflation test is valuable for investigating the mechanical response of the intact human cornea within physiological IOP ranges, providing benchmarks against which the numerical developments can be translated to clinic.

  2. d

    Inflation test on eye globe for: Experimental evaluation of stiffening...

    • search.dataone.org
    Updated May 3, 2025
    Share
    FacebookFacebook
    TwitterTwitter
    Email
    Click to copy link
    Link copied
    Close
    Cite
    Shao-Hsuan Chang; Yi-Chen Li; Dong Zhou; Ashkan Eliasy; Yi-Chen Li; Ahmed Elsheikh (2025). Inflation test on eye globe for: Experimental evaluation of stiffening effect induced by UVA/riboflavin corneal cross-linking using intact porcine eye globes [Dataset]. http://doi.org/10.5061/dryad.z8w9ghx9f
    Explore at:
    Dataset updated
    May 3, 2025
    Dataset provided by
    Dryad Digital Repository
    Authors
    Shao-Hsuan Chang; Yi-Chen Li; Dong Zhou; Ashkan Eliasy; Yi-Chen Li; Ahmed Elsheikh
    Time period covered
    Jan 1, 2020
    Description

    UVA/riboflavin corneal cross-linking (CXL) is a common used approach to treat progressive keratoconus. This study aims to investigate the alteration of corneal stiffness following CXL by mimicking the inflation of the eye under the in vivo loading conditions. Seven paired porcine eye globes were involved in the inflation test to examine the corneal behaviour. Cornea-only model was constructed using the finite element method, without considering the deformation contribution from sclera and limbus. Inverse analysis was conducted to calibrate the non-linear material behaviours in order to reproduce the inflation test. The corneal stress and strain values were then extracted from the finite element models and tangent modulus was calculated under stress level at 0.03 MPa. UVA/riboflavin cross-linked corneas displayed a significant increase in the material stiffness. At the IOP of 27.25 mmHg, the average displacements of corneal apex were 307 ± 65 μm and 437 ± 63 μm (p = 0.02) in CXL and PBS ...

  3. Not seeing a result you expected?
    Learn how you can add new datasets to our index.

Share
FacebookFacebook
TwitterTwitter
Email
Click to copy link
Link copied
Close
Cite
Shao-Hsuan Chang; Shao-Hsuan Chang; Yi-Chen Li; Dong Zhou; Ashkan Eliasy; Yi-Chen Li; Ahmed Elsheikh; Yi-Chen Li; Dong Zhou; Ashkan Eliasy; Yi-Chen Li; Ahmed Elsheikh (2022). Inflation test on eye globe for: Experimental evaluation of stiffening effect induced by UVA/riboflavin corneal cross-linking using intact porcine eye globes [Dataset]. http://doi.org/10.5061/dryad.z8w9ghx9f
Organization logo

Inflation test on eye globe for: Experimental evaluation of stiffening effect induced by UVA/riboflavin corneal cross-linking using intact porcine eye globes

Explore at:
binAvailable download formats
Dataset updated
Jun 3, 2022
Dataset provided by
Zenodohttp://zenodo.org/
Authors
Shao-Hsuan Chang; Shao-Hsuan Chang; Yi-Chen Li; Dong Zhou; Ashkan Eliasy; Yi-Chen Li; Ahmed Elsheikh; Yi-Chen Li; Dong Zhou; Ashkan Eliasy; Yi-Chen Li; Ahmed Elsheikh
License

CC0 1.0 Universal Public Domain Dedicationhttps://creativecommons.org/publicdomain/zero/1.0/
License information was derived automatically

Description

UVA/riboflavin corneal cross-linking (CXL) is a common used approach to treat progressive keratoconus. This study aims to investigate the alteration of corneal stiffness following CXL by mimicking the inflation of the eye under the in vivo loading conditions. Seven paired porcine eye globes were involved in the inflation test to examine the corneal behaviour. Cornea-only model was constructed using the finite element method, without considering the deformation contribution from sclera and limbus. Inverse analysis was conducted to calibrate the non-linear material behaviours in order to reproduce the inflation test. The corneal stress and strain values were then extracted from the finite element models and tangent modulus was calculated under stress level at 0.03 MPa. UVA/riboflavin cross-linked corneas displayed a significant increase in the material stiffness. At the IOP of 27.25 mmHg, the average displacements of corneal apex were 307 ± 65 μm and 437 ± 63 μm (p = 0.02) in CXL and PBS corneas, respectively. Comparisons performed on tangent modulus ratios at a stress of 0.03 MPa, the tangent modulus measured in the corneas treated with the CXL was 2.48 ± 0.69, with a 43±24% increase comparing to its PBS control. The data supported that corneal material properties can be well-described using this inflation methods following CXL. The inflation test is valuable for investigating the mechanical response of the intact human cornea within physiological IOP ranges, providing benchmarks against which the numerical developments can be translated to clinic.

Search
Clear search
Close search
Google apps
Main menu