Attribution 4.0 (CC BY 4.0)https://creativecommons.org/licenses/by/4.0/
License information was derived automatically
These original measurement data relate to the publication: J. Schaude, T. Hausotte: Atomic Force Microscope with an Adjustable Probe Direction and Integrated Sensing and Actuation, Nanomanufacturing and Metrology 5, pp. 519-148, https://doi.org/10.1007/s41871-022-00143-9. Please refer to this open access publication for a detailed description of the measurement setup and procedure.
All data are in ASCII-format. Each file contains six columns, where column one to three are the x, y, and z-coordinates of the positioning system, column four is the demodulated signal of the AFM (RAFM) and columns five and six are the raw signals of the z-interferometer (QA and QB).
Content of the folders
10_Calibrations: Repeated calibration of the AFM against the z-interferometer of the NMM-1.
20_Standstill-Measurements: Three standstill measurements for 90 s each.
30_Long-Term-Precision: Standstill measurements for 15 s every 10 min for in sum 18 hours.
40_Scans: Repeated closed-loop scans on a calibration grating.
50_SINCOS: Repeated movement of the stage in z-direction for 2 µm with the cantilever being in free air just before the sample.
Acknowledgement
This project was funded by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) –TRR 285 -Project-ID 418701707, subproject C05
Not seeing a result you expected?
Learn how you can add new datasets to our index.
Attribution 4.0 (CC BY 4.0)https://creativecommons.org/licenses/by/4.0/
License information was derived automatically
These original measurement data relate to the publication: J. Schaude, T. Hausotte: Atomic Force Microscope with an Adjustable Probe Direction and Integrated Sensing and Actuation, Nanomanufacturing and Metrology 5, pp. 519-148, https://doi.org/10.1007/s41871-022-00143-9. Please refer to this open access publication for a detailed description of the measurement setup and procedure.
All data are in ASCII-format. Each file contains six columns, where column one to three are the x, y, and z-coordinates of the positioning system, column four is the demodulated signal of the AFM (RAFM) and columns five and six are the raw signals of the z-interferometer (QA and QB).
Content of the folders
10_Calibrations: Repeated calibration of the AFM against the z-interferometer of the NMM-1.
20_Standstill-Measurements: Three standstill measurements for 90 s each.
30_Long-Term-Precision: Standstill measurements for 15 s every 10 min for in sum 18 hours.
40_Scans: Repeated closed-loop scans on a calibration grating.
50_SINCOS: Repeated movement of the stage in z-direction for 2 µm with the cantilever being in free air just before the sample.
Acknowledgement
This project was funded by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) –TRR 285 -Project-ID 418701707, subproject C05